Westerbeke 4.5 KW BGC -60Hz Instrukcja Operatora Strona 1

Przeglądaj online lub pobierz Instrukcja Operatora dla Silnik Westerbeke 4.5 KW BGC -60Hz. Westerbeke 4.5 KW BGC -60Hz Operator`s manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 95
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
OPERATOR'S MANUAL
WESTERBEKE
BCG
4.0KW
and
BCG 6.5KW
MARINE GASOLINE
GENERATOR SETS
Publication # 35729
Edition Two
March 1988
~
WESI'ERBEKE
WESTERBEKE CORPORATION
AVDNINDUSTRIAL
PARK, AVON, MA
02322.
TEL:
(617)
588-7700
Przeglądanie stron 0
1 2 3 4 5 6 ... 94 95

Podsumowanie treści

Strona 1 - WESI'ERBEKE

OPERATOR'S MANUAL WESTERBEKE BCG 4.0KW and BCG 6.5KW MARINE GASOLINE GENERATOR SETS Publication # 35729 Edition Two March 1988 ~ WESI'ERBEK

Strona 2 - Engines & Generators

BCG 4.()KW Marine Gasoline Generator Water Tempe ratu re Switch Fresh Water Air Bleed Control Pane AC Unit Data Tag Fuel Lift Pum Oil Pressure Switch

Strona 3 - SAFETY PRECAUTIONS

Fresh Water Coolant Fill Model Data Lube Oil Dir>stick 20 Amp DC Circuit Starter with Solenoid Westerbeke Generators BeG S.5KW Marine Gasoline Gene

Strona 4

BeG 6.SKW Marine Gasoline Generator Fuel Shut-oil So,lelnoi,d Intake Flame Arrestor Water Temperature Switc Control AC Lube Oil Filter 9 Carburetor wi

Strona 5 - I WESTERBEKE

BCG 4.0KW MARINE GASOLINE GENERATOR SET GENERAL SPECIFICATIONS Engine Type Governor Combustion Chamber Bore & Stroke Piston Displacement Firing Or

Strona 6 - Generators

INTAKE SYSTEM Carburetor (STD type) IGNITION SYSTEM General Distributor Spark Plug Thread Size Spark Plug Type FUEL SYSTEM General Fuel Lift Pump Fuel

Strona 7

BeG II.OKW SYSTEM SPECIFICATIONS Sea Water Flow, at 1800 rpm (measured before discharging into exhaust elbow) System Capacity (fresh water) LUBRICATIO

Strona 8 - Ordering

BeG 4.0KW SYSTEM SPECIFICATIONS AC GENERATOR General Voltage Rating (Volts AC) 60 Hertz (1800 rpm) 50 Hertz (1500 rpm) AC Circuit Breaker Generator Co

Strona 9

BCG S.!iKW MARINE GASOLINE GENERATOR SET GENERAL SPECIFICATIONS Engine Type Governor Combustion Chamber Bore & Stroke Piston Displacement Firing O

Strona 10

BCG 6.5KW SYSTEM SPECIFICATIONS INTAKE SYSTEM Carburetor (STD type) IGNITION SYSTEM General Distributor Spark Plug Thread Size Spark Plug Type FUEL SY

Strona 11

BCG 6.SKW SYSTEM SPECIFICATIONS Sea Water Flow, at 1800 rpm (measured before discharging into exhaust elbow) System Capacity (fresh water) LUBRICATION

Strona 12 - Westerbeke Generators

Gasoline with an ETHANOL content higher than 10% (E10) is not allowed and may void warranty.Engines & Generators

Strona 13

BCG S.5KW SYSTEM SPECIFICATIONS AC GENERATOR General Voltage Rating (Volts AC) 60 Hertz (1800 rpm) 50 Hertz (1500 rpm) AC Circuit Breaker Generator Co

Strona 14

INSTALLATION CHECKS General Since the crafts in which Westerbeke generators are installed vary in design, installation procedures will vary according

Strona 15

Rigging and Lifting The generator is fitted with lifting eyes. Rope or chain slings capable of supporting the generator's weight should be attac

Strona 16

Generator Mounting -Location The complete generator unit is mounted on lightweight rails by means of four flexible isolator mounts that help preventth

Strona 17 - & Stroke

Exhaust System IIWARNINGI CARBON MONOXIDE EXHAUST GAS IS DEADLY. Carbon monoxide is a dangerous gas that can cause unconsciousness and is potentially

Strona 18

Exhaust Back-Pressure The exhaust discharge hose must be of adequate size and minimal run to prevent excessive exhaust back-pressure. Exhaust back-p

Strona 19 - 90 - 125 (Ampere-Hours)

Dry stack-type exhaust systems (shown to the right) must be attached to the gen-erator engine's exhaust manifold by means of a flexible connecto

Strona 20 - ± 3 Hertz (5%)

Exhaust Elbow Installation The Westerbeke Corporation offers a 45°and 900exhaust elbow as well as an exhaust riser you can install on your generator.

Strona 21

Fuel System The generator must have its own fuel supply line; in other words, it must have fis own pickup tubes and primary filter/water separator.

Strona 22

.~ AMTI-SIPHON DEVICE OR ELECTRICALLY ~ OPERATED FUEL STOP VALVE -----~~~)"""";-:::";-:::::~/~-7::~~~F~U~E~L~TA~N~K~T:o:p ~L~

Strona 23 - MOUNTING

-----------------------------------"'''--~"-------------~, SAFETY PRECAUTIONS The following symbols appear in this manual to

Strona 24 - """u"i

Oil Drain Hose An oil sump drain hose is installed on the engine with the discharge end secured by a bracket at the front 01 the engine. Oil may be d

Strona 25 - ."

CAUTION DO NOT use a scoop-type through-hull fitting as a means of supplying sea water to the gen-erator. Water pressure against this type fitting, w

Strona 26 - :'

High Water Temperature Shutdown Switch (normally closed) A high water temperature switch is located on the thermostat housing. This switch will open

Strona 27 - 35 Ib-in, or 0.27

Ventilation The ventilation requirements of the generator sets include the following: combustion air is required for the engine cylinders; cooling ai

Strona 28 - _'-'...\

DESCRIPTION OF ENGINE CONTROL PANEL General The engine-mounted control panel is equipped with an ON switch, a START switch, and a STOP switch. The pan

Strona 29 - ELECTRICALLY

Optionsl Remote instrumenlllnd Remote Start Panels An optional remole instrument panel is available, which includes starting controls. This panel als

Strona 30 - DEFLECTION

PREPARATIONS FOR STARTING This section of the manual provides the operator with preparation, initial starting, break-in, starting (cold or warm), and

Strona 31 - Automatic Shutdown

STARTING PROCEDURE IWARNINGI CARBON MONOXIDE EXHAUST GAS IS DEADLY 1. Ventilate the generator compartment for a minimum of 5 minutes prior to starting

Strona 32 - + ) battery connection

Remote Starling Procedure The remote start panel is the same as the engine-mounted start panel except that it has a green LED light. When starting at

Strona 33 - 4.0KW, and page 17 for the

STOPPING PROCEDURE 1. Remove the AC electrical load from the generator and allow the generator to run for 3 to 5 minutes to sta-bilize its operating t

Strona 34

IMPORTANT PRODUCT SOFTWARE DISCLAIMER Product software of all kinds, such as brochures, drawings, technical data, operator's and worksho

Strona 35

Starting Under Cold Conditions Under extremely cold temperatures, the following conditions can occur. Follow the instructions listed below when opera

Strona 36 - (NORMRL

CARBURETOR AND FUEL SYSTEM Gasoline Use unleaded or leaded gasoline with an octane rating of 89 or better. In cold weather particularly, water vapor i

Strona 37 - C) before ap

Optional Fuel Filler HOSE FITTING A primary fuel filter of the water entrap-ment type should be installed between the fuel tank and the engine. A

Strona 38 - + path for voltage to

The engine-mounted electric lift pump contains the second fuel filter screen. This pump supplies fuel to the engine's carburetor during e

Strona 39

ELECTRICAL SYSTEM Engine 12·Voll DC Control Circuit The engine that drives the generator end has a 12-Volt DC electrical control circuit, as shown on

Strona 40

Testing the Batlery Charging CirclIil 1. AC Stator Winding,' O. 14 Ohms Lift the two AC leads off the bridge rectifier and measure with an ohmmet

Strona 41 - CLEANER

through the diodes located internally at these points. D. With the (-) negative lead still connected to point #4, touch point #5. The needle should no

Strona 42 - IIPPIIOII£II

DC CONTROL CIRCUIT WIRING DIAGRAM #35439 L - -4:0KV,--:-BC =--COIL CONNECTIONS 6,~KW Be -THRLJ 6186 [XHAUS T TEMP. SWITCH I Page 1 of 2 lJ-++-t--t--+-

Strona 43 - ~~~::-t--Magnet

DC CONTROL CIRCUIT WIRING DIAGRAM #35439 Page 2 of 2 SCHEMATIC DIAGRAM '+ 12VDC BATTERY BATTHW RETURN e ~u .. r .1.01. SHRT(R r I .., '.&qu

Strona 44 - IGNITION

OPTIONAL REMOTE START PANEL WIRING DIAGRAM # 35706 OPTIONRl REMOTE START PANEL (REAR VIEW} PART' 33183 r---------------------, I 116 RED I I I I

Strona 45 - + and -

FOREWORD Thank you for selecting a Westerbeke marine product for your use. We at Westerbeke are pleased to have you as a customer. Read this manual c

Strona 46 - O.C.Charge

:!:l ~ !Il. ~ til ~ Cl til :l ~ o iil 9K\1 8T SEE 0\1(,.30397 TO T81-2 TO T63-2 TO T82-1 TC Ttol2·2 TOT83-5 TO T81-1 TO HI3-j REMOTE INSTHUf\lENT PANE

Strona 47 - 't~

COOLING SYSTEM Description Westerbeke marine gasoline engines are designed and equipped for fresh water cooling. Heat produced in the engine by combu

Strona 48 - ;l'

Antifreeze Concentration Freezing Temperature ANTIFREEZE CONCENTRATION DATA % 13 23 30 35 45 50 60 , F 23 14 5 -4 -22 -40 -58 (' C) (-5) (-10)

Strona 49 - . "

FUNCTION OF MANIFOLD PRESSURE CAP From Coolant Tank to Coolant Yank COOLANT EXPANSION Coolant from the engine, when heated during the engine's o

Strona 50 - 1~~I~:r~25f~~2r~t~:t

Sea Waler Circuil The sea water flow is created by a belt-driven, positive displacement, neoprene impeller pump. The pump draws sea water dire

Strona 51

Governor and Water Pump Bell Tension iWARNINGI Never attempt to adjust the drive belt's tension whOa the engine is in operation. CAUTION Excessiv

Strona 52 - "r

Illustrated below is a typical Westerbeke engine's cooling system. Both fresh water and sea water flow through their independent cooling c

Strona 53 - PRESSURE

LUBRICATION SYSTEM Engine Oil For the engine's lubrication, use a lubricating oil designated for gasoline service. Use a good grade of oil havin

Strona 54

Engine Oil Change (10 include filler) 1. Draining the Oil Sump Discharge the old oil through the sump drain hose (at-tached at the front of the engi

Strona 55 - CRAUSHAFT

3. Filling the Oil Sump Add fresh oil through the oil filler cap on the valve cover. After refilling the oil, run the engine for a few moments while

Strona 56 - OVERHERT

TABLE OF CONTENTS Section ... Page GENERAL ...

Strona 57 - 44m#¥tlw*!2:o#i@>

Be GENERATOR The Be generator is a brushless, self-excited generator which requires only the driving force of the engine to produce an AC output. The

Strona 58 - IlliI'III1T?"

No-load Voltage Adjustment: BGG 4.0KW 1. Remove the louvered metal plate covering the terminal connections and the capacitor (see page 59). 2. Start t

Strona 59 - Crankcase

<:> '" C YO THE 11 PLUG IS SHOWN CONNECTED TO THE CAPACITOR ONLY FOR DEMON-STRATION PURPOSES. BeG 4.0KW GENERATOR H. Capacitor ::::,~-

Strona 60 -

No-Load Voltage Adjustment: BeG 6.5KW 1. Remove the louvered metal plate covering the terminal connections and the capacitor (see page 61). 2. Start t

Strona 61 - 220v 50 Hz

"'" • w -' N ... ~ ~ :: '" e '" "' THE 17 PLUG IS SHOWN CONNECTED TO THE CAPACITOR ONLY FOR DEMON-ST

Strona 62 - '"

Load Connections The generator's data plate gives the voltage, current and frequency rating of the generator. An AC wiring decal is affixed to t

Strona 63 - ~WARNINGI

Shore Power Connections If the installer connects shore power to the vessel's AC circuit, this must be done by means of the SHORE POWER/OFF/SHIPS

Strona 64 - "'"

GENERAL INFORMATION AND CARE OF THE GENERATOR Use of Electric Motors The power required to start an electric motor is considerably more than is requir

Strona 65 - 1 b 4 3

4-Pole Generator Voltage Load Speed Frequency 120V (110) 240V (220) Applied (rpm) (Hertz) Plants Plants None 1830 62 122 240 (1530) (52)

Strona 66 - ,,-->

ENGINE TROUBLESHOOTING Introduction The tables which follow indicate troubleshooting procedures based upon certain problem indicators, the probable c

Strona 67

TABLE OF CONTENTS (CONTINUED) LAY-UP & RECOMMISSIONING ... 80 SPARE PARTS LIST ...

Strona 68 - 60 120 240

Trouble Engine starts, runs and then shuts down. Back firing through carburetor. Engine overheats. 67 Possible Cause 1. Faulty automatic shutdown swit

Strona 69 - + ) at overspeed switch

Trouble Engine hunts. Engine misfires. High oil pressure. Low oil pressure. Westerbeke Generators 68 Possible Cause 1. Throttle linkage is binding. 2.

Strona 70

Trouble No DC charge to the starting battery. Black exhaust smoke Is discharged from the engine. Blue exhaust smoke is discharged from the exhaust. 69

Strona 71

MAINTENANCE AND ADJUSTMENTS Introduction This section contains a scheduled preventive maintenance program and several adjustment procedures the owner/

Strona 72

4. Adjust valve clearances. 5. Adjust the alternator and water pump drive belt tension, if required. 6. Adjust the engine's no-load speed, IT req

Strona 73

Preventive Maintenance (Generator) Maintenance on the generator end is minimal: 1. Keep the generator clean, dry, and well-ventilated. 2. Ensure that

Strona 74

Ignition Timing 1. Attach a timing light to the #1 spark plug and mark the front crankshaft pulley timing notch. Locate the timing pointer on the fr

Strona 75 - H the bear

Governor Adjustments Operate the generator set to bring the unit up to ITS operating temperature before attempting an adjustment. NOTE: If the govern

Strona 76 - -\--~~~

Governor Maintenance 1. Periodically lubricate the attaching points at both ends of the governor arm. Use a graphite lubricant or an equivalent. NOTE

Strona 77 - HuntinglBeculatjQo

Carburetor Adjustment 1. Idle Mixture Jet Disconnect the throttle linkage arm from the governor control arm and reduce the engine's speed with t

Strona 78 - 75 Westerbeke Generators

GENERAL Introduction This manual contains the equipment operating procedures as well as additional information needed to help the operator keep the ma

Strona 79 - ~~~Yl~~~~~~~

Torquing Cylinder Head Bolts Tighten the cylinder head bolts according to the sequence shown in the illustration below. Make sure the engine is cold

Strona 80 - SEQUENCE

Valve Clearance Adjustment: BCG 4.0KW NOTE: Retorque the cylinder head bolts before adjusting the engine's valves. 1. Remove the rocker cover a

Strona 81 - 9.4 Ib·ft (0.7 - 1.3 kg-m)

Spark Plugs To service the spark plugs, clean, gap or replace the plugs as needed. CAUTION DO NOT remove the spark plugs while the engine is hot.

Strona 82

LAY-UP AND RECOMMISSIONING General Many owners rely on their boatyards to prepare their craft, including engines and generators, for lay-up during th

Strona 83

Sea Water Circuit Close the through-hull sea cock. Remove the sea water intake hose from the sea cock. Place the end of this hose into a 5-gallon bu

Strona 84

Batteries If batteries are to be left on board during the lay-up period, make sure they are fully charged, and will remain that way, to prevent them f

Strona 85 - If batteries are

SPARE PARTS LIST Since a possibility exists in which the engine may need to be serviced at sea or while in a port other than your home port, certain s

Strona 86

TABLE OF STANDARD HARDWARE TIGHTENING TORQUES Unless stated otherwise for a specific assembly, use the following torque values when tightening standar

Strona 87 - 1.5 - 1.8

Cylinder head bolts* BCG 4.0KW BCG6.5KW TABLE OF TIGHTENING TORQUES 28.9 - 36.2 36.2 - 43.4 4.0 - 5.0 5.0 - 6.0 (*See the Torquing Cylinder Head Bolts

Strona 88

INDEX A Adjustment, Carburetor ...

Strona 89

Fresh Water Coolant Fill Exhaust Mani Lube Oil Dipstic 20 Amp DC Circu Breaker Zinc Anode Heat Ex.cha Weslerbeke Generators BeG 4.0KW Marine Gasoline

Strona 90

Choke, Electric ...

Strona 91

G Gasoline ...

Strona 92

Mounting - Location, Generator (Installation Checks) ... 20 N No-Load Volt

Strona 93

Replacing Filter Elements ...

Strona 94

Voltage Adjustment, No-Load, BCG 6.5KW ....... 60 W iWARNINGsl

Strona 95 - YOUR NOTES

YOUR NOTES Westerbeke Generators 92

Komentarze do niniejszej Instrukcji

Brak uwag